Rail Mount

Showing all 3 results

  • MAXVU Rail Limiter

    MAXVU Rail temperature and process limit is a device that’s easy to install and fast to setup with an easy to read Oled display.

    MAXVU Rail provides an affordable solution where secondary temperature limit protection is required, it offers a universal input and up to 3 outputs.

    Get a Quote Data Sheet

    [button href=”/wp-content/uploads/2018/12/DS-MVRL-2-US-1708.pdf” target=”_blank” icon=”no-icon” class=”btn-ghost”]Data Sheet[/button]

    Manufacturer Series Din Size
    West Control Solutions MAXVU Rail Rail Mount
  • PMA STB 55 Rail Line Temperature Limit Controller

    The safety temperature limiter STB 55 is used wherever thermal processes need to be monitored, and the plant switched into a safe condition in case of a fault.

    If the permissible temperature limit is reached or if a fault occurs in the monitoring equipment within the permissible temperature range (sensor break or short circuit, failure of a component within the device, fault in the software, failure or impermissible value of the supply voltage, etc.) the STB 55 switches off immediately. The alarm contact is activated, the “ALARM” LED in the front panel and the background lighting of the display light up, and the cause of the alarm appears in the display in plain text. In addition, a 24 VDC signal for external alarm signalling is available.

    Get a Quote Data Sheet

    [button href=”/wp-content/uploads/2018/12/STB-55-Datasheet.pdf” target=”_blank” icon=”no-icon” class=”btn-ghost”]Data Sheet[/button]

    Manufacturer Series Din Size
    West Control Solutions STB 55 Rail Mount
  • PMA TB 45 Precise Signal Monitoring Limit Controller

    The TB 45 temperature limiter is intended for precise, cost-effective signal monitoring & limiting tasks.

    The TB 45 can be used for heating and refrigeration processes. It is suitable for all thermocouple types and resistance type sensors. It is particularly designed for use in:

    All applications where an over or under temperature fault condition could present fire hazard or other hazard
    Heating system in buildings to DIN EN 12828
    Large hot-water boilers to DIN EN 12953-6
    Thermal transfer plants with organic heat transfer media to DIN 4754
    Oil-fired installations to DIN 4755
    Limit signalling function for any type of input signal

    Get a Quote Data Sheet

    [button href=”/wp-content/uploads/2018/12/TB-45-Datasheet-9498-737-48413.pdf” target=”_blank” icon=”no-icon” class=”btn-ghost”]Data Sheet[/button]

    Manufacturer Series Din Size
    West Control Solutions PMA TB 45 Rail Mount