Differential Pressure Transducers

View: 10 / 20 / ALL

  • Tel-Tru P521 Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 4/20mA, 0-5 V 1/4 NPT 0.25%

    Tel-Tru® series P521 standard differential pressure transducers are designed for end users and OEM's where ruggedness, high performance, and reliability are required at a competitive price. They are commonly used for hydraulics & pneumatics, laboratory & test, marine & offshore, pumps & compressors, and petrochemical applications.

    Data Sheet
  • Tel-Tru P523 Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Hazardous Location, Industrial 4/20mA, 0-5 V 1/4 NPT 0.25%

    Tel-Tru® series P523 hazardous differential pressure transducers are designed for end users and OEM's where ruggedness, high performance, and reliability are required at a competitive price. They are certified for hazardous locations as CSA/CUS certified Explosion Proof to Class I Div 1 & Class I Div 2 Groups A, B, C, and D. They are commonly used for hydraulics & pneumatics, laboratory & test, marine & offshore, pumps & compressors, and petrochemical applications.

    Data Sheet
  • Ashcroft AXL Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 0.5-4.5 V 1/2 NPT 1.00%

    Ashcroft® series AXLdp differential pressure transducers use Ashcroft®'s patented SiGlas™ variable capacitance sensor technology. The SiGlas™ sensor is used in conjunction with an Application Specific Integrated Circuit (ASIC) that allows for digital compensation of the analog output signal. The compensation allows this low cost sensor to provide repeatable and accurate low pressure measurements. These transducers are commonly used for flow measurements, room pressure control, fan control, and energy management.

    Data Sheet
  • Ashcroft CXL Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 4/20mA, 0-10 V 1/4 NPT, Barb 0.50%, 1.00%

    Ashcroft® series CXLdp differential pressure transducers utilize Ashcroft®‘s patented SiGlas™ variable capacitance sensor. This MEMS sensor provides extraordinary sensitivity and long term stability. New digital compensation is accomplished using a highly reliable application specific integrated circuit (ASIC).

  • Ashcroft DXL Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 4/20mA, 0-5 V, 1-5 V, 1-6 V, 0-10 V 1/4 NPT 0.25%, 0.5%, 1.00%

    Ashcroft® series DXLdp differential pressure transducers utilize Ashcroft®'s patented SiGlas™ technology that combines the high sensitivity of a variable capacitance transducer with the repeatability of a micro-machined, ultra-thin silicone diaphragm. The exclusive patented Ashcroft® SpoolCal™ actuator provides in-place system calibration without disturbing process tubes. These transducers are commonly used for high reliability HVAC, bio-pharm, bio-tech, room pressurization and control, and velocity pressure.

    Data Sheet
  • Ashcroft GC30 Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 1-5 V, PNP/NPN Barb 1.60%

    Ashcroft® series GC30 differential pressure transducers are a combined three-in-one digital pressure gauge, switch and transducer. They feature a highly reliable variable capacitance sensor using the patented Ashcroft® SiGlas™ sensor. This ultra-thin single crystal diaphragm provides inherent sensor repeatability and stability.

  • Ashcroft GC52 Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 4/20mA 1/4 NPT, Barb 0.50%

    Ashcroft® series GC52 differential pressure transducers utilize Ashcroft®‘s proven SiGlas™ silicon variable capacitance sensor technology in a wet-wet package ideal for applications where reliable, low differential pressure measurement is required with line (static) pressure to 300psi. In addition, the GC52 provides a linear flow output and (totalization) via square root extraction. Applications include pressurized & non-pressurized tank levels and flow (liquid/gas) measurement.

  • Ashcroft GC55 Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 4/20mA, 1-5 V 1/4 NPT 0.50%

    Ashcroft® series GC55 differential pressure transducers use two polysilicon thin film sensors to achieve a wet-wet, high differential, pressure measurement. Fully welded assembly of all stainless steel with high overpressure capability makes the GC55 ideal for fluid pump systems in applications such as: level measurement, pump monitoring and filter monitoring.

  • Ashcroft GL42 Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 4/20mA 1/4 NPT, Barb 0.50%, 1.00%

    Ashcroft® series GL42 differential pressure transducers utilize Ashcroft®'s patented SiGlas™ silicon variable capacitance sensor technology, ideal for applications where reliable, low differential pressure measurement is required with pressure from ±0.05″WC to 25″WC. They are typically used for filter monitoring, flow measurement, clean room monitoring, and fume hoods.

    Data Sheet
  • Ashcroft IXL Differential Pressure Transducer

    Item Type Output Connection Accuracy
    Industrial 4/20mA, 0-5 V, 1-5 V, 1-6 V, 0-10 V 1/4 NPT 0.25%, 0.50%

    Ashcroft® series IXLdp differential pressure transducers utilize Ashcroft®‘s patented SiGlas™ technology that combines the high sensitivity of a variable capacitance transducer with the repeatability of a micro-machined, ultra-thin silicone diaphragm. The IXLdp was designed for the measurement and control of very low pressure and flow in industrial and process plant environments. These transducers are commonly used for HVAC, fume hood control, lab/clean room pressurization, laminar flow, furnace/stack draft, leak detection, pollution monitoring, medical equipment, fan tracking, filter monitoring, and velocity measurements.