Pressure Instruments

View: 10 / 20 / ALL

  • Noshok 615 / 616 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 1-5 V, 1-6 V, 0-10 V, 1-11 V 1/4 NPT, 1/2 NPT, BSP, Flush, SAE 0.125%, 0.25% 1-10 psi, 15-10000 psi, 15000+ psi, Vacuum or Compound

    Noshok® series 615 & 616 feature current or voltage outputs, stainless steel wetted parts, and are CE compliant to suppress RFI, EMI and ESD. They are commonly used for construction, hydraulics & pneumatics, laboratory & test equipment, power generation, stamping & forming presses, and transportation.

  • SSI Technologies MGA Digital Pressure Gauge

    Dial Size Connection Mounting Accuracy
    2.5"(63mm) 1/4 NPT Lower 1.0% FS (Grade 1A)

    SSI® MGA-9V digital pressure gauges are stand alone 9V battery operated multi-functional gauges. They are lower cost with an accuracy of ±1.0% full scale for dry air and non-corrosive gas applications only.

    Data Sheet Buy Now
  • Ashcroft 1130 Differential Pressure Gauge

    Dial Size Mounting Ranges Wetted Material
    2.0"(50mm), 2.5"(63mm), 3.0", 3.5", 4.0"(100mm), 4.5", 6.0"(160mm) Lower, Back, In-Line, Panel Mount 15-1000 psid Aluminum, Brass, Stainless Steel

    Ashcroft® 1130 differential gauges use a piston design where small migration of the process media is permissible. They are recommended for high differential and high static pressures up to 6000psi. Body materials are available in Aluminum, Brass, and Stainless Steel, with Buna, Viton, or EPDM seals.

    Data Sheet
  • Ashcroft 4080 Indicating Pneumatic Transmitter

    Setpoint Type Deadband Connection Setpoint Ranges
    Adjustable Fixed 1/4 NPT < 150 psi, 150-3000 psi, > 5000 psi, Vacuum

    The Ashcroft® 4080 indicating pneumatic transmitter assists in the coordination of key functional areas within facilities. Transmitting data efficiently and accurately, it ensures operating economies and safety. A good product for process control and monitoring.

  • Ashcroft 4480 Non-Indicating Pneumatic Transmitter

    Setpoint Type Deadband Connection Setpoint Ranges
    Adjustable Fixed 1/2 NPT < 150 psi, 150-3000 psi, > 5000 psi, Vacuum

    The Ashcroft® 4480 non-indicating pneumatic transmitter assists in the coordination of key functional areas within facilities. Transmitting data efficiently and accurately, it ensures operating economies and safety. A good product for process control and monitoring.

  • Ashcroft A2 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 1-5 V, 1-6 V, 0-10 V, 0.5-4.5 V Ratiometric 1/8 NPT, 1/4 NPT, 1/2 NPT, BSP, SAE, Other 0.25%, 0.50%, 1.00% 15-10000 psi, Vacuum or Compound, Custom

    Ashcroft® A2 pressure transducers are ideal for a broad spectrum of pressure sensing requirements found in heavy industrial, test and measurement applications. They offer the instrument specifier a wide choice of construction and performance variables. These transducers are commonly used in test stands, compressor control, hydraulic systems, process automation, and pump and pneumatic systems control.

  • Ashcroft A4 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA 1/8 NPT, 1/4 NPT, 1/2 NPT, BSP, SAE, Other 0.25%, 0.50%, 1.00% 15-10000 psi, Vacuum or Compound

    Ashcroft® A4 pressure transmitters are idea for a broad spectrum of pressure sensing requirements where intrinisically safe or non-incendive hazardous location ratings are required. They are commonly used for oil field equipment, upstream oil and gas production, natural gas compression and transfer control, and alternative energy products.

  • Ashcroft DG25 Digital Pressure Gauge

    ,
    Dial Size Connection Mounting Accuracy
    2.5"(63mm) 1/8 NPT, 1/4 NPT, BSP, SAE, Other Lower 0.25% FS (Grade 3A), 0.5% FS (Grade 2A)

    Ashcroft® DG25 digital pressure gauges are suitable for use with a wide variety of pressure media in demanding industrial applications. They come with nine preprogrammed engineering units of measure to read pressure. Designed with the OEM in mind, they can easily be custom configured to meet unique requirements.

  • Ashcroft F Pressure Switch

    ,
    Setpoint Type Deadband Setpoint Ranges Item Type
    Adjustable Fixed < 150 psi, 150-3000 psi, Vacuum

    Ashcroft® series F line of compact, adjustable pressure switches is designed to satisfy most requirements for alarm, shutdown, control and interlock on a wide variety of process and equipment applications. All models feature hermetically sealed switch contacts and are approved for installation in Division I and II hazardous locations. They are reliable in offshore oil rigs, chemical & petrochemical plants, pulp & paper mills, engines, turbines & compressors, pipelines, and water & wastewater treatment plants.

  • Ashcroft GC30 Differential Pressure Sensor

    Item Type Switch Type Deadband Circuit
    OEM Electronic Adjustable PNP or NPN

    Ashcroft® series GC30 differential pressure transducers are a combined three-in-one digital pressure gauge, switch and transducer. They feature a highly reliable variable capacitance sensor using the patented Ashcroft® SiGlas™ sensor. This ultra-thin single crystal diaphragm provides inherent sensor repeatability and stability.

    Data Sheet