  • Gems 3100/3200 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 1-5 V, 1-6 V, 0.5-4.5 V, 0-10 V, 0.5-4.5 V Ratiometric 1/8 NPT, 1/4 NPT, BSP, SAE, Other 0.25%, 0.50% 15-10000 psi, Vacuum or Compound, Custom

    Gems® series 3100 & 3200 series sputtered thin film units offer unbeatable price performance in a compact construction for OEMs that need consistent high levels of performance, reliability, and stability. The 3200 series features thicker diaphragms and a pressure restrictor to withstand the rigors of cavitations or extreme pressure spikes.

  • Anfield T200 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0.5-4.5 V, 0-10 V 1/4 NPT, BSP, SAE 0.50% 15-10000 psi, Vacuum or Compound, Custom

    Anfield® series T200 pressure transducers are ideally suited for the industrial application where space constraints require a small body size. They are commonly used in industrial equipment, safety monitoring, and mobile equipment.

    Data Sheet
  • Ashcroft G2 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 1-5 V, 1-6 V, 0.5-4.5 V, 0-10 V, 0.5-4.5 V Ratiometric 1/8 NPT, 1/4 NPT, BSP, SAE, Other 1.00% 15-10000 psi, Vacuum or Compound

    Ashcroft® G2 pressure transducers combine performance with value to meet the demanding needs of the following applications: off-road equipment, construction machinery, performance racing, railroad/transportation, compressor control, HVAC & refrigeration, agricultural implements, process automation & control, hydraulic & pneumatic sensing, and pump monitoring.

    Data Sheet
  • Gems 1200/1600 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 1-5 V, 1-6 V, 0.5-5.5 V, 0-10 V 1/8 NPT, 1/4 NPT, 1/2 NPT, BSP, SAE, Other 0.50% 15-10000 psi, Vacuum or Compound, Custom

    Gems® series 1200 features stability and toughness via its CVD and ASIC design coupled with a thicker diaphragm. The 1600 series extends the packaging options by providing an all welded stainless steel back. They are commonly used for off-highway vehicles, natural gas equipment, semiconductor processing, power plants, refrigeration, robotics and HVAC.

  • Gems 2200/2600 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 1-5 V, 1-6 V, 0.5-5.5 V, 0-10 V, mV/V 1/8 NPT, 1/4 NPT, 1/2 NPT, BSP, SAE, Other 0.25% 15-10000 psi, Vacuum or Compound

    Gems® series 2200 features stability and accuracy in a variety of enclosure options. The 2600 series extends the packaging options by providing an all welded stainless steel back end. They are commonly used for off-highway vehicles, natural gas equipment, semiconductor processing, power plants, refrigeration, robotics, HVAC, and fuel tank pressure sensors.

  • SSI Technologies P51 Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 1-5 V, 0.5-4.5 V 1/8 NPT, 1/4 NPT, BSP, SAE, Other 0.50% 1-10 psi, 15-10000 psi, Custom

    SSI® series P51 MediaSensor™ family of bulk micro-machined, absolute, sealed, and gauge pressure sensors are for both harsh and benign media with superior accuracy over an operating temperature of -40°C to 105°C. These compact, robust sensors measure pressures from 3 to 5000psi and are well suited for a variety of automotive, industrial, and commercial applications.

    Data Sheet
  • Anfield TC Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 0.5-4.5 V, 0-10 V 1/8 NPT, 1/4 NPT, 1/2 NPT, BSP, SAE, Other 0.25%, 0.50% 15-10000 psi, Vacuum or Compound, Custom

    Anfield® series TC pressure transducers are great for applications where space is a constraint. They feature the availability of voltage or amperage output and are commonly used in automation processes, cranes, and road maintenance vehicles.

    Data Sheet
  • Anfield TG Pressure Transducer

    Output Connection Accuracy Ranges
    4/20mA, 0-5 V, 0.5-4.5 V, 0-10 V 1/8 NPT, 1/4 NPT, 1/2 NPT, BSP, SAE, Other 0.25%, 0.50% 15-10000 psi, Vacuum or Compound, Custom

    Anfield® series TG pressure transducers are general purpose low cost transducers suitable for a wide range of applications. They are commonly used in industrial equipment, safety monitoring, and mobile equipment.

  • Ashcroft K8 Pressure Transducer

    Output Connection Accuracy Ranges
    mV/V 1/8 NPT, 1/4 NPT, BSP, SAE, Other 0.50%, 1.00% 15-10000 psi

    Ashcroft® K8 pressure transducers are proven transducers incorporating polysilicon thin film technology in a miniature size and light weight package. They are commonly used in hydraulic, hand tool, machine tool, compressor, HVAC, medical, control valves, construction equipment, and all general purpose industrial process and OEM applications.

    Data Sheet
  • Ashcroft KM15 OEM Pressure Transducer

    Output Connection Accuracy Ranges
    1-5 V, 0.5-4.5 V Ratiometric 1/8 NPT, 1/4 NPT 0.50%, 1.00% 15-10000 psi, Vacuum or Compound

    The Ashcroft® KM15 OEM high volume pressure transducer is ideal when a durable and economical pressure transducer is needed. Combined high performance ASIC with proven polysilicon thin film sensor technology provides a highly accurate, stable, and rugged product platform. A perfect selection for satisfying most pressure measurement applications.